Reference Guide

System Input Max Power Capacity = 2382 W
Input Redundancy Reserve = 0 W
Max Power Conservation Mode = 11:20:08 02/27/2014
Power Available for Server Power-on = 1965 W
[Chassis Power Supply Status Table]
<
name> <Model> <Power State> <Input Current> <Input Volts> <Output Rated Power>
PS1 0CC6WF Online 0.3 A 208.0 V 1100 W
PS2 0GYH9V Online 0.3 A 209.0 V 1100 W
getpciecfg
Description Displays the FQDD of the PCIe slots and their mapping information and properties.
NOTE: To use this subcommand, you must have CMC Login User privilege.
NOTE: Lengthy PCIe card names and server slot names are truncated when the
assignments for all PCIe slots are displayed.
Synopsis
racadm getpciecfg [-c <FQDD>]
Input
-a — Use this option to display the assignment of PCIe slots .
-c — Use this option to select a specic PCIe adapter or Virtual Adapter.
FQDD — FQDD of the selected PCIe slot
Example
Displays FQDDs of all the PCIe slots:
racadm getpciecfg
<PCIe Slot#> <FQDD>
PCIe slot 01 PCIE.ChassisSlot.1
PCIe slot 02 PCIE.ChassisSlot.2
PCIe slot 03 PCIE.ChassisSlot.3
PCIe slot 04 PCIE.ChassisSlot.4
PCIe slot 05 PCIE.ChassisSlot.5
PCIe slot 06 PCIE.ChassisSlot.6
PCIe slot 07 PCIE.ChassisSlot.7
PCIe slot 08 PCIE.ChassisSlot.8
Displays the assignment of PCIe slots and Vitual Adapters:
racadm getpciecfg -a
<PCIe Slot#> <Name> <pwrState> <Server Slot Name> <Server
Slot#>
PCIe slot-1 PCIe Card 1 ON
SLOT-04 4
PCIe slot-2 Not Present N/A
UNMAPPED N/A
PCIe slot-3 PCIe Card 3 OFF
SLOT-03 3
PCIe slot-4 Extension PCIe Card 3 ON
SLOT-03 3
PCIe slot-5 PCIe Card 5 OFF
SLOT-02 2
PCIe slot-6 Not Present N/A
UNMAPPED N/A
PCIe slot-7 PCIe Card 7 ON
localhost 1
PCIe slot-8 Not Present N/A
UNMAPPED N/A
48