Reference Guide
<Name> <Type> <Presence> <Active WWN/
MAC>>
<Partition
Status>>
<Assignment
Type>>
Server-1-A IDRAC-
Controller
Present 18:A9:9B:FD:C4:
DF
N/A Factory
Gigabit
Ethernet
Present 00:0A:00:0A:
00:00
Unknown IO-Identity
Server-3-A Gigabit
Ethernet
Present 4:8F:
69:FC:E8:F1
Unknown Factory
Server-4-A 10 GbE KR/3 Present F8:DB:
88:3D:A2:7A
Unknown FlexAddress
FCoE-WWN Present 20:01:F8:DB:
88:3D:A2:7A
Unknown FlexAddress
getmodinfo
Description
Displays conguration and status information for all modules or a specied module (server, storage sled, switch,
CMC, fan unit, blower, power supply unit, chassis, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The Service Tag eld is blank for modules that do not have Service Tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]ra
Input
• -m < module > — Species the module for which the conguration and status information is required. The
default command (no options) displays information about all the major components in the chassis.
<module > can be one of the following values:
– server-n , where n = 1 to 4
– server-nx , where n = 1 to 4; x = a to d
– switch-n , where n = 1 or 2
– pcie-n , where n = 1 to 8
– CMC-n , where n = 1
– fan-n , where n = 1 to 8
– ps-n , where n = 1 to 2
– chassis
– main-board
– io-cable
– fpc cable
• -A — Does not display the headers and labels in the output.
Example
• racadm getmodinfo -m switch-1
• <module> <presence> <pwrState> <health> <svcTag> Switch-1 Present ON OK
CG09074
• racadm getmodinfo
<module> <presence> <pwrState
>
<health> <svcTag> <node Id>
Chassis
Present ON OK ST0MP19 N/A
43