Reference Guide

To use this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber
Channel, and Inniband.
Synopsis
racadm getioinfo
racadm getioinfo [-m <module>]
racadm getioinfo [-m <module>] [-s]
Input
-mSpecies the module or device. The <module> must be switch — <n>, where n = 1–2
-s — Displays the stack information.
Example
racadm getioinfo
<IO> <Name> <Type> <Presenc
e>
<POST> <Power> <Role> <Secure
Mode>
<Mode>
switch-
1
N/A None Not
Present
N/A N/A N/A No N/A
switch-
2
PE 10
Gigabit
KR
Present OK ON Master No N/A
racadm getioinfo -m switch-1
<
IO> <Name> <Type>
<Presenc
e> <POST> <Power> <Role>
<SecureM
ode> <Mode>
Switch-
1
1GBE PASS-
THROUGH
MODULE
Gigabit
Ethernet
Present OK ON Master No N/A
getled
Description
Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).
To use this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m < module > — Species the module whose LED settings you want to view.
< module > can be one of the following:
server-n where n=1 or 4
switch-n where n=1 or 2
chassis
CMC active
Example For CMC:
racadm getled -m server-4
<module> <LED state> server-4 Blinking
38