Reference Guide
• racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl {r0|r1|
r5|r6|r10|r50|r60} [-wp {wt|wb}] [-rp {nra|ra|ara}] [-ss
{1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -
pdkey:<comma separated PD FQDDs>
• [-dcp {enabled|disabled|default}] [-name <VD name>] [-size
<VD size> {b|k|m|g|t}] [-cc]
• racadm raid discardcache:RAID.ChassisIntegrated.1-1
• racadm raid changepolicy:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 -wp {wt|wb} -rp {nra|ra|ara} -
dcp {enabled|disabled|default} racadm raid
rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD
name>
• racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild
<value>>] [-bgi <value>] [-reconstruct <value>] [-
checkconsistency <value>] [-ccmode {abortonerror | normal}]
[-copybackmode {off | on | onwithsmart}] [-lb {auto |
disabled}] [-prunconfigured {yes | no}] racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 racadm raid
cancelrebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
raid
Description Allows you to execute commands to control RAID arrays.
To use this subcommand for CMC you must have Chassis Administartor privilege.
Synopsis
racadm raid
Example
• Monitor Health of Storage root node
racadm raid get status
Storage Root Node Status : Ok
This command retrieves the controllers keys, (FQDDs.)
• Monitor and Inventory all Controllers connected to the server
racadm raid get controllers
racadm raid get controllers -o
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o -p <property names separated by comma>
This command displays the filtered property values for all returned controller objects.
• Monitor and Inventory all batteries connected to the controller
racadm raid get batteries --refkey <controller FQDDs
separated by comma>
This command displays all battery keys connected to the controllers referred to as refkeys.
racadm raid get batteries --refkey <controller FQDDs
separated by comma > -o
This command is an optimized version and displays all battery objects for the controller FQDD.
racadm raid get batteries --refkey <controller FQDDs
separated by comma > -o -p <property names separated by comma>
76