Reference Guide

mainboard
perc
expander
hdd
perc-fqdd, where fqdd is FQDD of the PERC.
expander-fqdd, where fqdd is FQDD of the Storage Expander.
hdd-fqdd, where fqdd is FQDD of the HDD.
Example
Retrieve the version for a server 4
racadm getversion -m server-4
Retrieve the Lifecycle Controller component versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3
Retrieve the Lifecycle Controller BIOS versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3 -f bios
Retrieve the version for all modules:
racadm getversion
Retrieve the iDRAC version in all the servers that are attached to the chassis:
racadm getversion -f idrac
ifconfig
Description Displays the contents of the network interface table.
To use this subcommand, you must have Execute
Diagnostic Commands or Configure iDRAC permission.
Synopsis
racadm ifconfig
Example
$ racadm ifconfig
eth0 Link encap:Ethernet HWaddr
00:1D:09:FF:DA:23
inet addr:10.35.155.136
Bcast:10.35.155.255
Mask:255.255.255.0
UP BROADCAST RUNNING
MULTICAST MTU:1500
Metric:1
RX packets:2550665
errors:0 dropped:0 overruns:0
frame:0
TX packets:0 errors:0
dropped:0 overruns:0
carrier:0
collisions:0 txqueuelen:
1000
RX bytes:272532097
(259.9 MiB) TX bytes:0
(0.0 B)
57