Reference Guide
Unmapped N/A
<PCIe Slot#> <Virtual Adapter#> <Server Slot Name <Server Slot>
9 1 SLOT-01 1
9 2 SLOT-02 2
9 3 SLOT-03 3
9 4 SLOT-04 4
10 1 SLOT-01 1
10 2 SLOT-02 2
10 3 SLOT-03 3
10 4 SLOT-04 4
• Displays the properties of a PCIe slot selected using FQDD:
racadm getpciecfg -c pcie.chassisslot.1
• Displays the properties of a Virtual Adapter selected using FQDD:
racadm getpciecfg -c RAID.ChassisIntegrated.2-1-4
getpminfo
Description Displays power management status information.
To use this subcommand, you must have CMC Login User
privilege.
Synopsis
racadm getpminfo
Example
racadm getpminfo
[Real-Time Power Statistics]
System Input Power = 600
W (188 BTU/hr)
Peak System Power = 600
W (188 BTU/hr
Peak System Power Start Time =
16:02:10 01/16/2008
Peak System Power Timestamp =
06:32:55 01/26/2009
Minimum System Power = 400
W (177 BTU/hr)
Minimum System Power Start Time =
22:43:21 01/21/2008
Minimum System Power Timestamp =
06:32:55 01/26/2009
System Idle Power = 68 W
(188 BTU/hr)
System Potential Power = 68 W
(188 BTU/hr)
System Input Current Reading = 31.2
A
[Real-Time Energy Statistics]
System Energy
Consumption = 6.4 kWh
System Energy Consumption Start
Time = 16:02:10 01/16/2008
System Energy Consumption
Timestamp = 16:02:10 01/16/2008
48