Users Guide
9. Configure iDRAC network settings as required. by default, iDRAC LAN is enabled with static IP
configured. To determine the default static IP address with an Enterprise license, go to Server
Overview → Setup → iDRAC. You can also determine the static IP address with an Express license.
Go to
Server Overview → Server-Slot → Setup → iDRAC.
10. Provide the IO module with an external management IP address(if applicable) in the CMC web
interface. You can get the IP address by clicking I/O Module Overview, and then clicking Setup.
11. Connect to each iDRAC through the web interface using default root account credential to
complete any necessary configuration.
12. Turn on the servers and install the operating system.
NOTE: The default local account credential is root (user name) and calvin (user password).
Daisy chain FX2 CMC network connection
If you have multiple chassis in a rack, you can reduce the number of connections to the management
network by daisy-chaining up to ten chassis together. You can reduce the number of management
network uplink connections required from ten to one.
When daisy-chaining chassis together, GB is the uplink port and STK is the stacking (cable consolidation)
port. Connect the Gb ports to the management network or to the STK port of CMC in a chassis that is
closer to the network. Connect the STK port only to a Gb port further from the chain or network.
The following figure illustrates the arrangement of cables for four daisy-chained chassis, each with active
CMCs.
25