Important Notes
•
CMC network default setting is Static with IP address of "192.168.0.120". Complete the CMC
network setup by directly connecting a client system on the same network. For more information,
see the
Chassis Management Controller for PowerEdge FX2 Version 1.10 User's Guide
available at
dell.com/support/manuals
.
•
Connecting the STK/Gb2 port of the CMC at the back of the chassis to the management network
can cause network disruption if not properly cabled and configured in CMC. Before using the
STK/Gb2 port of the CMC, see the PowerEdge FX2 Version 1.10 Owner's Manual available at
dell.com/support/manuals.
•
The PCIe cards are allocated to sleds based on the sled type, for more information, see the
Chassis Management Controller for PowerEdge FX2 Version 1.10 User's Guide available at
dell.com/support/manuals.
This is applicable to Dell PowerEdge FX2s chassis.
•
Some advanced features require CMC enterprise license. For more information about the CMC
licenses, see the
Chassis Management Controller for PowerEdge FX2 Version 1.10 User's Guide
available at
dell.com/support/manuals
.
•
Storage features using Storage Sleds require a storage license. For more information about
storage licenses, see the Chassis Management Controller for PowerEdge FX2 Version 1.20 User's
Guide available at
dell.com/support/manuals
.
•
When Certificate Validation is “Enabled”, FQDN of the system should be provided. If the IP address
of the Domain Controller is specified when the certificate validation is enabled, the Active
Directory login may not work.
•
The
cfgRacTuneIdracDNSLaunchEnable
object and the "iDRAC Launch Method" setting on the
Chassis Overview > Setup > General
CMC Graphical Interface requires the Chassis Configuration
Administrator privilege.
•
When saving Server Profile under
Server Overview > Setup > Profiles
, the list of characters that
are not supported for the Profile Name include the characters - hash(#), comma(,), and question
mark(?).
Known Issues
•
Issue (162141):
Non-iSCSI MAC addresses may be displayed when you run the
racadm
getmacaddress
command using the
"-t iscsi
" option.
•
Resolution:
None. Extraneous non-iSCSI MAC addresses may be ignored.
•
Issue (174272):
After disabling the Flex Address, the "getmacaddress -c" racadm command
displays the MAC address assigned on the extension slots of quarter-width sleds.
Resolution:
Refer to the CMC GUI, it is accurate.
•
Issue (180253):
PCIe card device name displayed in iDRAC GUI and CMC GUI are not same for
Broadcom/Qlogic 10G card.
Resolution:
Refer to the iDRAC GUI, it is accurate and current.