Reference Guide

FQDD = RAID.Modular.2-1
Physical Disk Slots = 0-15
Connected Server = SLOT-01
Controller Mode Capability = HBA and RAID
Display format of storage sled information when the storage mode is “split
single host”.
racadm getstoragemoduleinfo -c System.Modular.03
Storage-2 FQDD = System.Modular.03
Chassis Slot = 3
Name = SLOT-03
Model = PowerEdge FD332
Status = Not OK
Service Tag = 8748596
Asset Tag = KLOP98656
Intrusion State = Closed
Storage Mode = Split single host
Number of Controllers = 2
FQDD = RAID.Modular.3-1
Physical Disk Slots = 0-7
Connected Server = SLOT-01
Controller Mode Capability = HBA
FQDD = RAID.Modular.3-2
Physical Disk Slots = 8-15
Connected Server = SLOT-1
Controller Mode Capability = HBA
Display format of storage sled information when the storage mode is “Split
dual host”.
racadm getstoragemoduleinfo -c System.Modular.03
Storage-3 FQDD = System.Modular.03
Chassis Slot = 3
Name = SLOT-03 (Storage)
Model = PowerEdge FD332
Status = OK
Service Tag = 4657248
Asset Tag = ERHJ57834
Intrusion State = Closed
Storage Mode = Split dual host
Number of Controllers = 1
FQDD = RAID.Modular.3-1
Physical Disk Slots = 0-7
Connected Server = SLOT-01
Controller Mode Capability = RAID
FQDD = RAID.Modular.2-1
Physical Disk Slots = 8-15
Connected Server = SLOT-2
Controller Mode Capability = HBA and RAID
Display format when storage sleds are not installed on the CMC FX2 or CMC
FX2s system.
racadm getstoragemoduleinfo
This command is not supported on this configuration.
59