Reference Guide
getmodinfo
Description
Displays configuration and status information for all modules or a specified module
(server, storage sled, switch, CMC, fan unit, blower, power supply unit, chassis, main-
board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The Service Tag field is blank for modules that do not have Service Tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]ra
Input
• -m < module > — Specifies the module for which the configuration and status
information is required. The default command (no options) displays information
about all the major components in the chassis.
<module > can be one of the following values:
– server-n , where n = 1 to 4
– server-nx , where n = 1 to 4; x = a to d
– switch-n , where n = 1 or 2
– pcie-n , where n = 1 to 8
– CMC-n , where n = 1
– fan-n , where n = 1 to 8
– ps-n , where n = 1 to 2
– chassis
– main-board
– io-cable
– fpc cable
• -A — Does not display the headers and labels in the output.
Example
• racadm getmodinfo -m switch-1
• <module> <presence> <pwrState> <health> <svcTag> Switch-1
Present ON OK CG09074
• racadm getmodinfo
<module> <presenc
e>
<pwrStat
e>
<health> <svcTag> <node Id>
Chassis
Present ON OK ST0MP19 N/A
Main-
Board
Present ON OK N/A N/A
Storage-
2
Present OFF Not OK 6666666 N/A
Storage-
3
Present OFF Not OK 6666666 N/A
Storage-
4
Present OFF OK 6666666 N/A
46