Reference Guide
10 GbE
KR
00:90:FA:
51:31:F1
F0:1F:AF:88:22:7E(active)
NOTE: 10 GbE KR/3 — The value 3 indicates the protocol type.
getioinfo
Description Displays general information about the I/O modules on the chassis.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as
Ethernet, Fiber Channel, and Infiniband.
Synopsis
racadm getioinfo
Example
racadm getioinfo
<IO> <Name> <Type> <Presence> <POST> <Power> <Role>
switch-1 N/A None Not
Present
N/A N/A N/A
switch-2 PE 10
Gigabit KR
Present OK ON Master
getled
Description Displays the LED settings on a module: blinking, not blinking, or unknown
(for empty slots).
To use this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m < module > — Specifies the module whose LED settings you want to
view.
< module > can be one of the following:
• server-n where n=1 or 4
• switch-n where n=1 or 2
• chassis
• CMC active
Example For CMC:
• racadm getled -m server-4
40