Reference Guide

cmc.alert.audit
cmc.alert.audit.lic
cmc.alert.audit.warning
cmc.alert.audit.lic.critical
Input
get - Displays the list of event filter settings.
set - Configures the actions and notifications for a given event filter
configuration.
-c - Alert descriptor of the specific event filter.
-n - The notification to be sent when the event occurs. Valid values are
all, snmp, ipmi, email, or none. You can append multiple notifications
separated by a comma. You cannot enter the values all or none with
other notifications.
-r - Event generation interval. This is applicable only to the temperature
statistics subcategory - tmps. You can use this option as a stand-alone or
with -n .
NOTE: If both event generation interval and notifications are
configured and there is an error while configuring the notifications, the
event generation interval is not set. The valid values are from 0–365. 0
disables the event generation.
Example
Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
Display eventfilter configurations for a specific category. For example,
audit:
racadm eventfilters get -c cmc.alert.audit
Display eventfilter configurations for a specific subcategory. For example,
licensing under the audit category:
racadm eventfilters get -c cmc.alert.audit.lic
Display eventfilter configurations for a specific severity. For example,
warning under the audit category:
racadm eventfilters get -c cmc.alert.audit.warning
Display eventfilter configurations for a specific severity and subcategory.
For example, a severity of warning in the subcategory licensing under
audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
Configure using subcategory as a parameter. For example, all
configurations under the licensing subcategory in the audit category are
assigned poweroff as action and all notifications are enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
Configure using subcategory and severity as parameters. For example, all
Information events under the licensing subcategory in the audit category
are assigned poweroff as action and all notifications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -
n none
Configure the event generation interval for temperature statistics:
racadm eventfilters set -c
cmc.alert.system.tmps.warning -r 10
27