Reference Guide
NOTE: This input is available in IOA only.
• -q— Displays or modifies the quick deploy parameters.
• -n— Specifies the number of reserved IP addresses for quick deploy. The
valid values are 2 and 4.
Output None
Example
• racadm deploy -m server-8 -s 192.168.0.20 255.255.255.0
192.168.0.1
The server was deployed successfully.
The deploy command generates an error when used on the extension
slot of a multi-slot server.
• racadm deploy -m server-9 192.168.0.11 255.255.255.0
192.168.0.1
ERROR: Server in slot 9 is an extension of the server in slot 1.
• rracadm deploy -m server-7 -u root -p <default root
user password> -s -6 ::/64 :: 10
eventfilters
Description
Gets, sets, and displays the list of event filter settings.
To use this subcommand with the get option, you must have the CMC Login
User privilege.
Synopsis
• racadm eventfilters <eventfilters command type>
• racadm eventfilters get -c <alert descriptor>
• racadm eventfilters set -c <alert descriptor>-n <notifications>
• racadm eventfilters set -c <alert descriptor>-r <recurrence>
NOTE: The general format of an alert descriptor:
cmc.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are
optional. A severity cannot precede a subcategory.
Valid category values are:
• System
• Config
• Updates
• Audit
Valid severity values are:
• Critical
• Warning
• Informational
Valid examples of alert descriptors are:
• cmc.alert.all
26