Default 100
cfgChassisRedundancyPolicy (Read/Write)
Description Sets the redundancy policy of the chassis.
Legal Values
0 (no redundancy)
1 (Grid redundancy)
3 ( Redundancy Alerting Only)
Default 3 ( Redundancy Alerting Only)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis
operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description Indicates the amount of redundant power (in Watts) in reserve that can be
utilized in the event of an AC grid or PSU failure. This value is 0 if the
Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisPowerClear (Write Only)
Description Resets cfgChassisMinPower and cfgChassisMaxPowerCapacity, when set to
1.
Legal Values None
Default None