Reference Guide
For CMC: This object property is read only. Specifies the difference in number
of seconds, from the UTC/GMT. This value is negative if the current time
zone is west of Greenwich.
Legal Values - 720–7800
Default 0
cfgRacTuneSledNetworkUplink
Description Configuration of all the sleds that contain an internal network switch (for
example, the FM120).
Legal Values
• 1 - Standard (aggregated)
• 2 - Network Adaptor Isolation (Enhanced Security)
• 3 - Isolated Networks
Default 1
cfgRacTuneUserBlkEnable
Description Blocks the login for maximum of 5 minutes after 5 unsuccessful login
attempts. The login using any interface such as WSMAN or GUI is blocked
after 5 unsuccessful attempts.
NOTE: This is applicable only to configure the user privilege.
Legal Values
• 1 – Enabled
• 0 – Disabled
Default 0 — Disabled
Example
racadm getconfig -g cfgRacTuning [-m server-<n>] -o
<
object name
> <
object value
>
cfgRacTuneRemoteRacadmEnable=1
cfgRacTuneWebserverEnable=1
cfgRacTuneHttpPort=80
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
cfgRacTuneIpBlkEnable=0
cfgRacTuneIpBlkFailCount=5
cfgRacTuneIpBlkFailWindow=60
cfgRacTuneIpBlkPenaltyTime=300
114