Users Guide

用途
racadm getdcinfo
示例
l racadm getdcinfo
Group1I/OType:GigabitEthernet
Group2I/OType:FibreChannel8
Group3I/OType:InfinibandDDR
<IO#><Type><State>
switch-1GigabitEthernetOK
switch-2GigabitEthernetOK
switch-3FibreChannel8OK
switch-4FibreChannel8OK
switch-5InfinibandDDROK
switch-6InfinibandDDROK
<Server#><Presence><DC1Type><DC1State>
<DC2Type><DC2State>
server-1 Present FibreChannel 8 OK
Infiniband DDR OK
server-2 Not Present None N/A
None N/A
server-3 Present FibreChannel 8 OK
Infiniband DDR OK
server-4 Not Present None N/A
None N/A
server-5 Not Present None N/A
None N/A
server-6 Not Present None N/A
None N/A
server-7 Not Present None N/A
None N/A
server-8 Not Present None N/A
None N/A
server-9 Extension(1) FibreChannel 8 OK
Infiniband DDR OK
server-10 Not Present None N/A
None N/A
server-11 Not Present None N/A
None N/A
server-12 Not Present None N/A
None N/A
server-13 Not Present None N/A
None N/A
server-14 Not Present None N/A
None N/A
server-15 Not Present None N/A
None N/A
server-16 Not Present None N/A
None N/A
getflexaddr
显示整个机箱的启用/禁用状态。如果使用 -i,则该命令将显示每个插槽的 MACs/WWN
用途
racadm getflexaddr [-i <插槽编号>]
<插槽编号> = 1 16
选项
注: 下面是带有多插槽服务器的示例输出。
注: 要使用此子命令,必须具有 "CMC Login User" CMC 用)权限。
注: 如果机箱上的 FlexAddress 未激活,该命令将显示服务器分配的 MAC/WWN 地址。如果插槽为空,该命令将返回错误信息。