User's Manual

68 Configuring CMC to Use Command Line Consoles
There are up to six IOMs on the managed system. To connect to an IOM,
type:
connect switch-
n
where n is an IOM label a1, a2, b1, b2, c1, and c2.
IOMs are labeled A1, A2, B1, B2, C1, and C2. (See Table 10-1 for an
illustration of the placement of IOMs in the chassis.) When you reference the
IOMs in the connect command, the IOMs are mapped to switches as shown
in Table 3-4.
NOTE: There can only be one IOM connection per chassis at a time.
NOTE: You cannot connect to passthroughs from the serial console.
To connect to a managed server for debugging, use the command connect
server-n, where -n is the slot number of the server you wish to debug. When
you connect to a server, binary communication is assumed and the escape
character is disabled. If the iDRAC is not available, you will see a No route
to host error message. Ensure that your server is inserted properly and the
iDRAC has had time to complete the boot routine.
For details on how to connect through a serial connection, see "Configuring
CMC to Use Command Line Consoles" on page 57.
Table 3-4. Mapping I/O Modules to Switches
I/O Module Label Switch
A1 switch-a1
A2 switch-a2
B1 switch-b1
B2 switch-b2
C1 switch-c1
C2 switch-c2