Using the LCD Panel Interface 443
Table C-10. Chassis/Enclosure Status
Item Description
User Define Name Example: “Dell Rack System”. This is settable via CMC CLI
or Web GUI
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
Model Number Example "PowerEdgeM1000"
Power Consumption Current power consumption in watts
Surplus for Peak
Performance
The surplus for peak performance value is the difference
between the System Input Power Cap and the Power
Required for Peak Performance (sum of the Maximum Input
Power Allocated to Servers and the Maximum Input Power
Allocated to Chassis Infrastructure). The value for Surplus for
Peak Performance is displayed in both the watts and BTU/h
units.
Peak Power Peak power consumed in watts
Minimum Power Minimum power consumed in watts
Ambient
Temperature
Current ambient temperature in degrees Celsius
Service Tag The factory-assigned service tag
CMC redundancy
mode
Non-Redundant or Redundant
PSU redundancy
mode
Non-Redundant, AC Redundant, or DC Redundant
Table C-11. Fan Status
Item Description
Name/Location Example: Fan1, Fan2, etc.
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
RPM Current fan speed in RPM