User's Manual

242 Power Management
NOTE: This action powers off the chassis (chassis, servers, IOMs, iKVM, and
power supplies). The CMCs remain powered on, but in virtual standby state; a
power supply unit and fans provide cooling for the CMCs in this state. The
power supply will also provide power to the fans that will be running at low
speed.
Power Cycle System (cold boot)
— Powers off and then reboots the
system (cold boot). This option is disabled if the chassis is already
powered
OFF
.
NOTE: This action powers off and then reboots the entire chassis (chassis,
servers which are configured to always power on, IOMs, iKVM, and power
supplies).
Reset CMC
— Resets the CMC without powering off (warm reboot).
(This option is disabled if the CMC is already powered off).
NOTE: This action only resets the CMC. No other components are affected.
Non-Graceful Shutdown
— This action forces a non-graceful power
off of the entire chassis (chassis, servers, IOMs, iKVM, and power
supplies). This does not attempt to cleanly shutdown the operating
system of the servers prior to powering off.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example, cause
the system to reset).
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm chassisaction -m chassis <
action
>
where
<
action
> is
powerup, powerdown, powercycle,
nongraceshutdown or reset.
Executing Power Control Operations on an IOM
You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.