User's Manual

Power Management 225
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Power Management
tab. The
Power Budget Status
page
displays.
Table 8-5 through Table 8-11 describe the information displayed on the
Power Budget Status page.
See "Configuring Power Budget and Redundancy" on page 233 for
information about configuring the settings for this information.
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm getpbinfo
NOTE: For more information about getpbinfo, including output details, see
"getpbinfo" on page 346.
Table 8-5. Real-Time Power Statistics
Item Description
System Input Power Displays the current cumulative power consumption of all
modules in the chassis measured from the input side of the
PSUs. The value for system input power is indicated in
both watts and BTU/h units.
Peak System Power Displays the maximum system level input power
consumption since the value was last cleared. This property
allows you to track the maximum power consumption by
the system (chassis and modules) recorded over a period of
time. Click the Configuration sub-tab on the Budget
Status page to clear this value. The value for peak system
power is indicated in both watts and BTU/h units.