User's Manual

170 Using FlexAddress
Activating FlexAddress
FlexAddress is delivered on a Secure Digital (SD) card that must be inserted
into the CMC to provide the chassis-assigned WWN/MAC IDs. To activate
the FlexAddress feature, perform several required updates; if you are not
activating FlexAddress these updates are not required. The updates, which
are listed in the table below, include server module BIOS, I/O mezzanine
BIOS or firmware, and CMC firmware. You must apply these updates before
you enable FlexAddress. If these updates are not applied, the FlexAddress
feature may not function as expected.
To ensure proper deployment of the FlexAddress feature, update the BIOS
and the firmware in the following order:
1
Update all mezzanine card firmware and BIOS.
2
Update server module BIOS.
3
Update iDRAC firmware on the server module.
4
Update all CMC firmware in the chassis; if redundant CMCs are present,
ensure both are updated.
5
Insert the SD card into the passive module for a redundant CMC module
system or into the single CMC module for a non-redundant system.
Component Minimum required version
Ethernet mezzanine card - Broadcom
M5708t
Boot code firmware 4.4.1 or later
iSCSI boot firmware 2.7.11 or later
PXE firmware 4.4.3 or later
FC mezzanine card - QLogic QME2472 BIOS 2.04 or later
FC mezzanine card - Emulex LPe1105-
M4
BIOS 3.03a3 and firmware 2.72A2 or
later
Server Module BIOS (PowerEdge
M600) BIOS 2.02 or later
(PowerEdge M605) BIOS 2.03 or later
PowerEdgeM600/M605 LAN on
motherboard (LOM)
Boot code firmware 4.4.1 or later
iSCSI boot firmware 2.7.11 or later
iDRAC Version 1.11 or later
CMC Version 1.10 or later