User's Manual
Using the CMC Web Interface 157
on connection speed. When the internal update process begins, the page
automatically refreshes and the Firmware update timer displays.
Additional items to note:
• Do not use the
Refresh
button or navigate to another page during the
file transfer.
• To cancel the process, click
Cancel File Transfer and Update
- this
option is available only during file transfer.
• Update status displays in the
Update State
field; this field is
automatically updated during the file transfer process. Certain older
browsers do not support these automatic updates. To manually refresh
the
Update State
field, click
Refresh
.
NOTE: The update may take several minutes for the CMC or Server.
When the update is complete, the updated Server will no longer be present
on the Updatable Components page.
Recovering iDRAC Firmware Using the CMC
iDRAC firmware is typically updated using iDRAC facilities such as the
iDRAC Web interface, the SM-CLP command line interface, or operating
system specific update packages downloaded from support.dell.com. See the
iDRAC Firmware User’s Guide for instructions for updating the iDRAC
firmware.
If the iDRAC firmware becomes corrupted, as could occur if the iDRAC
firmware update progress is interrupted before it completes, you can use the
CMC Web interface to update its firmware.
If the CMC detects the corrupted iDRAC firmware, the iDRAC is listed on
the Updatable Components page. See "Viewing the Current Firmware
Versions" on page 151 for instructions to display the Updatable Components
page.