User's Manual
156 Using the CMC Web Interface
on connection speed. When the internal update process begins, the page
automatically refreshes and the Firmware update timer displays.
Additional items to note:
• Do not use the
Refresh
button or navigate to another page during the
file transfer.
• To cancel the process, click
Cancel File Transfer and Update
- this
option is available only during file transfer.
• Update status displays in the
Update State
field; this field is
automatically updated during the file transfer process. Certain older
browsers do not support these automatic updates. To manually refresh
the
Update State
field, click
Refresh
.
NOTE: No file transfer timer is displayed when updating IOMINF firmware. The
update process will cause a brief loss of connectivity to the IOM device since the
device will perform a restart when the update is complete.
When the update is complete, the new firmware is updated and displayed on
the Updatable Components page.
Updating the Server iDRAC Firmware
NOTE: The iDRAC (on a Server) will reset and become temporarily unavailable
after firmware updates have been uploaded successfully.
1
Log back in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Update
tab. The
Updatable Components
page appears.
4
Click the Server name. The
Firmware Update
page appears.
5
In the
Firmware Image
field, enter the path to the firmware image file on
your management station or shared network, or click
Browse
to navigate to
the file location.
6
Click
Begin Firmware Update
. A dialog box prompts you to confirm the
action.
7
Click
Yes
to continue. The
Firmware Update Progress
section provides
firmware update status information. A status indicator displays on the
page while the image file uploads. File transfer time can vary greatly based