User's Manual
100 Using the CMC Web Interface
NOTE: The slot name setting in the CMC Web interface always overrides any
change you make to the display name in the iDRAC interface.
To edit a slot name:
1
Log in to the CMC Web interface.
2
Select
Servers
in the
Chassis
menu in the system tree.
3
Click the
Setup
tab. The
Slot Names
page displays.
4
Type the updated or new name for a slot in the
Slot Name
field. Repeat
this action for each slot you want to rename.
5
Click
Apply
.
Setting the First Boot Device for Servers
The First Boot Device page allows you to specify the CMC first boot device
for each server. This may not be the actual first boot device for the server or
even represent a device present in that server; instead it represents a device
that will be used by the CMC as the first boot device in regard to that server.
You can set the default boot device and you can also set a one-time boot
device so that you can boot a special image to perform tasks such as running
diagnostics or reinstalling an operating system.
The boot device that you specify must exist and contain bootable media.
Table 5-2 lists the boot devices that you can specify.
Table 5-2. Boot Devices
Boot Device Description
PXE Boot from a Preboot Execution
Environment (PXE) protocol on
the network interface card.
Hard Drive Boot from the hard drive on the
server.
Local CD/DVD Boot from a CD/DVD drive on the
server.