Users Guide
• None — This mode does not enable you to monitor or manage the chassis component through
iDRAC, OS, or Lifecycle Controller.
• Monitor — This mode enables you to monitor the chassis components but you cannot perform
any firmware update through iDRAC, OS, or Lifecycle Controller.
• Manage and Monitor — This mode enables you to monitor the chassis components and update
the CMC firmware using DUP through iDRAC, OS, or Lifecycle Controller.
Configuring Chassis Management at Server Mode Using RACADM
To enable the Chassis Management at server using RACADM, use the following commands:
• To disable Chassis Management at Server mode, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 0
• To change Chassis Management at Server mode to monitor, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 1
• To change Chassis Management at server mode to manage and monitor, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 2
32