Reference Guide
NOTE: Chassis name is a maximum of 64 non-extended ASCII
characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.root
setflexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
To use this subcommand, you must have the Chassis Configuration
Administrator privilege.
If the fabric type is determined to be Infiniband, the operation is canceled and
the command returns an error. If the FlexAddress feature is not activated, the
command returns an error.
NOTE: The server must be turned off to change the slot state. All servers
must be turned off to change the fabric state. The MAC/WWN addresses
must be managed locally (not by an external console) to use this
command.
Synopsis
racadm setflexaddr [-i <slot#> <state>][-f <fabricName>
<state>]
< slot# > = 1 to 4
< fabricName > = A1 or A2
< state > = 0 or 1
where 0 is disable and 1 is enable.
Input
• -i <slot#> <state> — Enables or disables FlexAddress for the specified slot.
• -f <fabricName> <state> — Enables or disables FlexAddress for the
specified fabric.
Example
• racadm setflexaddr -i 1 0
Slot 1 FlexAddress state set successfully
• racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
• racadm setflexaddr -f idrac 1
setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the
Debug Administrator privilege on CMC. To enable the servers to blink or
74