Reference Guide

Reset servers 1 and 3.
racadm racreset -m server-1 -m server-3
racresetcfg
Description Resets CMC configuration to factory default settings.
NOTE: To use this, you must have the Chassis Administrator privilege.
Synopsis
racadm racresetcfg [-m <module>] [-c <feature>]
Input
-m : <module> — Must be one of the following values:
chassis — default state, if -m is not specified.
server-n, where n=1–4
switch-n, where n=1–2
-c : <feature> — Must be one of the following values:
ad — Reset Active Directory properties to the default value. The
default setting is “disabled”.
pcap — Reset Power Cap properties to the default value.
flex — Reset FlexAddress properties to the default value. The default
setting is “enabled”.
NOTE: The –c option is valid with only <module=chassis>.
Example
Perform reset of configuration data to defaults for server-1 module
racadm racresetcfg -m server-1
Perform reset of power cap feature.
racadm racresetcfg -c pcap
Perform reset of configuration data to default for switch-1 module
racadm racresetcfg -m switch-1
racresetpcie
Description Resets the PCIe server mapping in the chassis to factory defaults.
NOTE:
To use this subcommand for CMC, you must have the Chassis
Administrator privilege.
This command cannot run successfully, if any blade server is
powered on.
Synopsis
racadm racresetpcie
remoteimage
Description Connects, disconnects, or deploys a media file on a remote server.
70