Reference Guide

Session information - getssinfo
Sensor information - getsensorinfo
Switches information (IO Module) - getioinfo
Mezzanine card information (Daughter card) - getdcinfo
All modules information - getmodinfo
Power budget information - getpbinfo
KVM information - getkvminfo
NIC information (CMC module) - getniccfg
Redundancy information - getredundancymode
Trace log information - gettracelog
RAC event log - getraclog
System event log - getsel
Output The following information is displayed when the racdumpsubcommand is
processed:
General system/RAC information
Coredump
Session information
Process information
Firmware build information
Example
racadm racdump
===============================================================================
General System/RAC Information
===============================================================================
CMC Information:
CMC Date/Time = Wed, 28 Nov 2007 11:55:49 PM
CMC Version = X08
Last Firmware Update = Wed Nov 21 21:37:56 2007
Hardware Version = 2
Current IP Address = 10.35.155.160
Current IP Gateway = 10.35.155.1
Current IP Netmask = 255.255.255.0
DHCP Enabled = 1
MAC Address = 00:55:AB:39:10:0F
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
Register DNS CMC Name = 0
DNS CMC Name = cmc-servicetag
Current DNS Domain =
Chassis Information:
System Model = PowerEdgeM1000eControlPanel
System AssetTag = 00000
Service Tag =
Chassis Name = Dell Rack System
Chassis Location = [UNDEFINED]
Power Status = ON
===============================================================================
68