Reference Guide

LOM Status:
NIC Selection = Dedicated
Link Detected = Yes
Speed = 10Mb/s
Duplex Mode = Half Duplex
getpbinfo
Description Displays power budget status information.
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power = 90 W
Peak System Power = 93 W
Peak System Power Timestamp = 20:28:32 03/04/2014
Minimum System Power = 83 W
Minimum System Power Timestamp = 20:28:02 03/04/2014
Overall Power Health = OK
Redundancy = Yes
System Input Power Cap = 3371 W
Redundancy Policy = Redundancy Alerting Only
System Input Max Power Capacity = 2382 W
Input Redundancy Reserve = 0 W
Max Power Conservation Mode = 11:20:08 02/27/2014
Power Available for Server Power-on = 1965 W
[Chassis Power Supply Status Table]
<name> <Model> <Power State> <Input Current> <Input Volts> <Output Rated
Power
>
PS1 0CC6WF Online 0.3 A 208.0 V 1100 W
PS2 0GYH9V Online 0.3 A 209.0 V 1100 W
getpciecfg
Description Displays the FQDD of the PCIe slots and their mapping information and
properties.
NOTE: To use this subcommand, you must have CMC Login User
privilege.
Synopsis
racadm getpciecfg [-c <FQDD>]
Input
-a — Use this option to display the assignment of PCIe slots .
-c — Use this option to select a specific PCIe adapter or Virtual Adapter.
FQDD — FQDD of the selected PCIe slot
50