Reference Guide
– server-n , where n = 1 to 4
– server-nx , where n = 1 to 4; x = a to d
– switch-n , where n = 1 or 2
– pcie-n , where n = 1 to 8
– CMC-n , where n = 1
– fan-n , where n = 1 to 8
– ps-n , where n = 1 to 2
– chassis
– main-board
– io-cable
– fpc cable
• -A — Does not display the headers and labels in the output.
Example
• racadm getmodinfo -m switch-1
• <module> <presence> <pwrState> <health> <svcTag> Switch-1
Present ON OK CG09074
• racadm getmodinfo
<module> <presenc
e>
<pwrStat
e>
<health> <svcTag> <node Id>
Chassis
Present ON OK ST0MP19 N/A
Main-
Board
Present ON OK N/A N/A
Fan-1 Present ON OK N/A N/A
Fan-2 Present ON Unknown N/A N/A
Fan-3 Present ON Unknown N/A N/A
Fan-4 Present ON Unknown N/A N/A
Fan-5 Present ON OK N/A N/A
Fan-6 Present ON Unknown N/A N/A
Fan-7 Present ON Unknown N/A N/A
Fan-8 Present ON Unknown N/A N/A
PS-1 Present Online OK N/A N/A
PS-2 Present Online OK N/A N/A
CMC Present Primary OK N/A N/A
Switch-1 Present ON OK 0000000 N/A
Switch-2 Present ON OK N/A N/A
46