Reference Guide
• cmc.alert.audit
• cmc.alert.audit.lic
• cmc.alert.audit.warning
• cmc.alert.audit.lic.critical
Input
• get - Displays the list of event filter settings.
• set - Configures the actions and notifications for a given event filter
configuration.
• -c - Alert descriptor of the specific event filter.
• -n - The notification to be sent when the event occurs. Valid values are
all, snmp, ipmi, email, or none. You can append multiple notifications
separated by a comma. You cannot enter the values all or none with
other notifications.
• -r - Event generation interval. This is applicable only to the temperature
statistics subcategory - tmps. You can use this option as a stand-alone or
with -n .
NOTE: If both event generation interval and notifications are
configured and there is an error while configuring the notifications, the
event generation interval is not set. The valid values are from 0–365. 0
disables the event generation.
Example
• Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
• Display eventfilter configurations for a specific category. For example,
audit:
racadm eventfilters get -c cmc.alert.audit
• Display eventfilter configurations for a specific subcategory. For example,
licensing under the audit category:
racadm eventfilters get -c cmc.alert.audit.lic
• Display eventfilter configurations for a specific severity. For example,
warning under the audit category:
racadm eventfilters get -c cmc.alert.audit.warning
• Display eventfilter configurations for a specific severity and subcategory.
For example, a severity of warning in the subcategory licensing under
audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
• Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
• Configure using subcategory as a parameter. For example, all
configurations under the licensing subcategory in the audit category are
assigned poweroff as action and all notifications are enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
• Configure using subcategory and severity as parameters. For example, all
Information events under the licensing subcategory in the audit category
are assigned poweroff as action and all notifications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -
n none
• Configure the event generation interval for temperature statistics:
racadm eventfilters set -c
cmc.alert.system.tmps.warning -r 10
27