Reference Guide

NOTE: This input is available in IOA only.
-q— Displays or modifies the quick deploy parameters.
-n— Specifies the number of reserved IP addresses for quick deploy. The
valid values are 2 and 4.
Output None
Example
racadm deploy -m server-8 -s 192.168.0.20 255.255.255.0
192.168.0.1
The server was deployed successfully.
The deploy command generates an error when used on the extension
slot of a multi-slot server.
racadm deploy -m server-9 192.168.0.11 255.255.255.0
192.168.0.1
ERROR: Server in slot 9 is an extension of the server in slot 1.
rracadm deploy -m server-7 -u root -p <default root
user password> -s -6 ::/64 :: 10
eventfilters
Description
Gets, sets, and displays the list of event filter settings.
To use this subcommand with the get option, you must have the CMC Login
User privilege.
Synopsis
racadm eventfilters <eventfilters command type>
racadm eventfilters get -c <alert descriptor>
racadm eventfilters set -c <alert descriptor>-n <notifications>
racadm eventfilters set -c <alert descriptor>-r <recurrence>
NOTE: The general format of an alert descriptor:
cmc.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are
optional. A severity cannot precede a subcategory.
Valid category values are:
System
Config
Updates
Audit
Valid severity values are:
Critical
Warning
Informational
Valid examples of alert descriptors are:
cmc.alert.all
26