Reference Guide
cfgKvmMapping
Description Selects the server to which the KVM connects
Legal Values
1[a-d]-4[a-d]
Default 0 (Unmapped)
cfgAlerting
This group is enables or disables SNMP event trap alerting and sets the event filter.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
• 1 (true)
• 0 (false)
Default None
cfgAlertingSourceEmailName
Description Specifies the e-mail address used to send e-mail notifications when an event
occurs.
Legal Values None
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
132