Reference Guide
cfgChassisPowerCapBTU (Read/Write)
Description Indicates the maximum power consumption limit (in BTU/hr) for the entire
chassis. The command generates an error if server throttling is necessary to
achieve the power goal based on the value for this setting.
Legal Values 1839-11501 BTU/hr
Default 11501 BTU/hr
cfgChassisPowerCapFBTU (Read/Write)
Description Indicates the maximum power consumption limit (in BTU/hr) for the entire
chassis. Use cfgChassisCapFBTU when power consumption is to be changed
regardless of whether server throttling is required. The command generates
an error if the value for this setting is lower than the minimum power required
for the chassis configuration.
Legal Values 9264 - 56931 BTU/hr
Default 56931 BTU/hr
cfgChassisPowerCapPercent (Read/Write)
Description Indicates the power consumption limit as a percentage. The percentage is
computed mathematically as the minimum power + (percent * (maximum
power - minimum power)). The command generates an error if server
throttling is necessary to achieve the power goal based on the value for this
setting.
Legal Values 16 - 100
NOTE: If the specified percent is lower than the minimum value, the
CMC will set the value to the minimum value.
Default 100
cfgChassisPowerCapFPercent (Read/Write)
Description Indicates the power consumption limit as a percentage. The percentage is
computed mathematically as the minimum power + (percent * (maximum
power - minimum power)). Use cfgChassisPowerCapFPercent when power
consumption is to be changed regardless of whether server throttling is
required.
Legal Values 16 - 100
NOTE: If the specified percent is lower than the minimum value, the
CMC will set the value to the minimum value.
129