User's Manual
92 Using the CMC Web Interface
• MC-
• Chassis
• Housing-Left
• Housing-Right
• Housing-Center
• The strings
Server-1
through
Server-16
may be used, but only for
the corresponding slot. For example,
Server-3
is a valid name for slot 3,
but not for slot 4. Note that
Server-03
is a valid name for
any
slot.
NOTE: To change a slot name in the Web interface, you must have Chassis
Configuration Administrator privilege.
NOTE: The slot name setting in the Web interface resides on the CMC only. If a
server is removed from the chassis, the slot name setting does not remain with the
server.
NOTE: The slot name setting in the CMC Web interface always overrides any
change you make to the display name in the iDRAC interface.
To edit a slot name:
1
Log in to the CMC Web interface.
2
Select
Servers
in the
Chassis
menu in the system tree.
3
Click the
Setup
tab. The
Slot Names
page displays.
4
Type the updated or new name for a slot in the
Slot Name
field. Repeat
this action for each slot you want to rename.
5
Click
Apply
.
Setting the First Boot Device for Servers
The First Boot Device page allows you to specify the boot device for each
server. You can set the default boot device and you can also set a one-time
boot device so that you can boot a special image to perform tasks such as
running diagnostics or reinstalling an operating system.
The boot device that you specify must exist and contain bootable media.
Table 5-2 lists the boot devices that you can specify.