User's Manual
402 Using the LCD Panel Interface
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front
panel LCD for each type of component in the chassis.
Table C-9. CMC Status
Item Description
Name/Location Example: CMC1, CMC2
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
IP Address Only shows on active CMC.
MAC Address Only shows on active CMC.
Firmware Version Only shows on active CMC.
Table C-10. Chassis/Enclosure Status
Item Description
User Define Name Example: “Dell Rack System”. This is settable via CMC CLI
or Web GUI
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
Model Number Example "PowerEdgeM1000"
Power Consumption Current power consumption in watts
Peak Power Peak power consume in watts
Minimum Power Minimum power consume in watts
Ambient
Temperature
Current ambient temperature in degrees Celsius
Service Tag The factory-assigned service tag
CMC redundancy
mode
Non-Redundant or Redundant
PSU redundancy
mode
Non-Redundant, AC Redundant, or DC Redundant