User's Manual

400 Using the LCD Panel Interface
Critical POST Err: POST sensor, System
management interrupt
initialization failed
System Management Interrupt
initialization failure
Critical POST Err: POST sensor, BIOS
shutdown test failed
BIOS shutdown test failure
Critical POST Err: POST sensor, BIOS
POST memory test failed
BIOS POST memory test failure
Critical POST Err: POST sensor, Dell
remote access controller
configuration failed
Dell Remote Access Controller
configuration failure
Critical POST Err: POST sensor, CPU
configuration failed
CPU configuration failure
Critical POST Err: POST sensor, Incorrect
memory configuration
Incorrect memory configuration
Critical POST Err: POST sensor, POST
failure
General failure after video
Critical Hdwar version err: Version Change
sensor, hardware incompatibility
was asserted
Incompatible hardware was
detected
Critical Hdwar version err: Version Change
sensor, hardware incompatibility
(BMC firmware) was asserted
Hardware is incompatible with the
firmware
Critical Hdwar version err: Version Change
sensor, hardware incompatibility
(BMC firmware and CPU
mismatch) was asserted
CPU and firmware not compatible
Critical Mem Overtemp: Memory sensor,
correctable ECC <DIMM
Location> was asserted
Memory module overheating
Critical Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC was
asserted
South bridge memory failed
Table C-8. Server Status Screen (continued)
Severity Message Cause