User's Manual

Using the LCD Panel Interface 393
Critical CMC <number> Standalone:
Micro Controller sensor for CMC,
non-redundant was asserted
CMC no longer redundant.
NOTE: This will only show if the
standby CMC was removed or has
failed.
Critical Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, all
event logging disabled was asserted
The CMC cannot log events.
Critical Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, log
full was asserted
Chassis device detects that only
one entry can be added to the CEL
before it is full.
Warning Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, log
almost full was asserted
Chassis event log is 75% full.
Table C-4. Fan Status Screens
Severity Message Cause
Critical Chassis Fan <number> Status:
Fan sensor for Chassis Fan, failure
event
The speed of the specified fan is
not sufficient to provide enough
cooling to the system.
Table C-5. IOM Status Screens
Severity Message Cause
Warning I/O Module <number> Status:
Module sensor for I/O Module,
transition to non-critical from OK
was asserted
The IO module was good, but now
having fabric mismatch or link
tuning mismatch.
Critical I/O Module <number> Status:
Module sensor for I/O Module,
transition to critical from less
severe was asserted
The I/O module has a fault. The
same error can also happen if the
I/O module is thermal-tripped.
Table C-3. Enclosure/Chassis Status Screen (continued)
Severity Message Cause