380 CMC Property Database Group and Object Definitions
Read only. Displays the BMC MAC address of the specified server.
# cfgServerNic1MacAddress
Read only. Displays the MAC address of the server NIC.
# cfgServerNic2MacAddress
Read only. Displays the MAC address of the server NIC.
cfgServerPriority
Sets the priority level allotted to the server in the chassis for power budgeting
purposes.
Configuration range: 1–9 in descending priority, where 1 holds the highest
priority
Default: 1
cfgServerNicEnable
Enables or disables LAN channel.
Configuration options: 0 (disable), 1 (enable)
cfgServerIPMIOverLanEnable
Enables or disables IPMI LAN channel.
Configuration options: 0 (disable), 1 (enable)
Example
racadm getconfig -g cfgServerInfo -i 1
# cfgServerInfoIndex=1
cfgServerSlotNumber=1
# cfgServerServiceTag=JGPRQ61
cfgServerName=Server-1
# cfgServerBmcMacAddress=00:11:43:FD:B7:2A
# cfgServerNic1MacAddress=00:11:43:FD:B7:2A
# cfgServerNic2MacAddress=N/A