User's Manual

354 CMC Property Database Group and Object Definitions
cfgRhostsFwUpdateIpAddr
The IP address of the network SMTP server. The SMTP server transmits
e-mail alerts from the CMC (if the alerts are configured and enabled).
Configuration options: A string representing a valid SMTP server IP address.
For example, 192.168.0.55.
Default: 0.0.0.0
cfgRhostsFwUpdatePath
Specifies the TFTP path where the CMC firmware image file exists on the
TFTP server. The TFTP path is relative to the TFTP root path on the TFTP
server.
NOTE: The server may still require you to specify the drive (for example, C).
Legal value: String of up to 255 characters.
cfgRhostsSmtpServerIpAddr
Specifies the IP address of the network SMTP server, which transmits e-mail
alerts from the CMC if the alerts are configured and enabled.
Legal value: A string representing a valid TFTP server IP address. For
example, 192.168.0.55.
Default: 0.0.0.0
Example
racadm getconfig -g cfgRemoteHosts
cfgRhostsFwUpdateTftpEnable=1
cfgRhostsFwUpdateIpAddr=127.0.0.1
cfgRhostsFwUpdatePath=m13_0417.bin
cfgRhostsSmtpServerIpAddr=localhost.localdomain
cfgUserAdmin
NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and
cfgUserAdminPrivilege are interrelated; changing the value of one property causes
the value of the other property to change. For example, if a user does not have login
privilege, the user is disabled by default. When you enable the user by changing the