User's Manual

302 RACADM Subcommands
Examples:
racadm getconfig -g cfgLanNetworking
Displays all of the configuration properties (objects) that are contained in
the group
cfgLanNetworking
(see "cfgLanNetworking" on page 349).
racadm getconfig -f myrac.cfg
Saves all group configuration objects from the CMC to
myrac.cfg
.
racadm getconfig -h
Displays a list of the available configuration groups on the CMC.
racadm getconfig -u root
Displays the configuration properties for the user named root.
getdcinfo
NOTE: To use this subcommand, you must have CMC Login User privilege.
Description
Displays general I/O module and daughter card configuration information.
NOTE: Fabric verification for server DCs is performed only when the chassis is
powered on. When the chassis is on standby power, the iDRACs on the server
modules remain powered off and thus are unable to report the server's DC fabric
type. The DC fabric type may not be reported in the CMC user interface until the
iDRAC on the server is powered on.
Usage
racadm getdcinfo
Example
racadm getdcinfo
Group 1 I/O Type : Gigabit Ethernet
Group 2 I/O Type : None
Group 3 I/O Type : None
<IO#> <Type> <State>
switch-1 Gigabit Ethernet OK