User's Manual
Power Management 221
5
Select the
Server Power Throttling Enabled
check box.
6
Click
Apply
to save your changes.
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm config -g cfgChassisPower -o
cfgChassisServerPowerThrottling <
option
>
where <
option
> is 0 (disable), or 1 (enable).
Executing Power Control Operations on the Chassis
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
NOTE: Power control operations affect the entire chassis. For power control
operations on an IOM, see "Executing Power Control Operations on an IOM" on
page 222. For power control operations on servers, see "Executing Power Control
Operations on a Server" on page 223.
The CMC enables you to remotely perform several power management
actions, such as an orderly shutdown, on the entire chassis (chassis, servers,
IOMs, iKVM, and PSUs).
Using the Web Interface
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Power Management
tab. The
Power Budget Status
page displays.
4
Click the
Control
sub-tab. The
Power Management
page displays.
5
Select one of the following
Power Control Operations
by clicking its radio
button:
•
Power On System
— Turns on the system power.
•
Power Off System
— Turns off the system power.
•
Reset CMC
— Resets the CMC without powering off (warm reboot).
(This option is disabled if the CMC is already powered off).
NOTE: This action only resets the CMC. No other components are affected.
•
Power Cycle System
— Power off, then reboot (cold boot) the system.