User's Manual
Using the CMC Web Interface 145
5
For additional information, review the online help page by clicking the
Help
link and review "Using FlexAddress" on page 151.
Configuring FlexAddress
If you purchase FlexAddress with your chassis, it will be installed and active
when you power up your system. If you purchase FlexAddress separately, you
must install the SD feature card using the instructions in the Chassis
Management Controller (CMC) Secure Digital (SD) Card Technical
Specification document. See support.dell.com for this document.
The server must be off before you begin configuration. You can enable or
disable FlexAddress on a per fabric basis. Additionally, you can enable/disable
the feature on a per slot basis. Once you enable the feature on a per-fabric
basis, you can then select slots to be enabled. For example, if Fabric-A is
enabled, any slots that are enabled will have FlexAddress enabled only on
Fabric-A. All other fabrics will use the factory-assigned WWN/MAC on the
server.
Selected slots will be FlexAddress enabled for all fabrics that are enabled. For
example, it is not possible to enable Fabric-A and B, and have Slot 1 be
FlexAddress enabled on Fabric-A but not on Fabric-B.
NOTE: You can also configure FlexAddress using the command line interface. For
more command information, see "Using FlexAddress" on page 151.
Chassis-Level Fabric and Slot FlexAddress Configuration
At the chassis level, you can enable or disable the FlexAddress feature for
fabrics and slots. FlexAddress is enabled on a per-fabric basis and then slots
will be selected for participation in the feature. Both fabrics and slots must be
enabled to successfully configure FlexAddress.
Fabric Displays the type of fabric.
Server-Assigned Displays the server-assigned
WWN/MAC addresses that are
embedded in the controller's hardware.
Chassis-Assigned Displays the chassis-assigned
WWN/MAC addresses that are used for
the particular slot.