Owner's Manual

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc1.0/en/readme/CMC_README.TXT[10/26/2012 2:32:07 PM]
getpbinfo). User can, however, power OFF one or more server(s) to lower the
current DC Power allocation and re-attempt setting a lower value for System
Max AC Power Limit (if desired) or simply configure the limit prior to
powering on the server blades.
NOTE: Please refer to the Datacenter Capacity Planner (DCCP) tool at
www.dell.com/calc for capacity planning.(186670)
#####################################################################
KNOWN ISSUES FOR DOCUMENTATION
#####################################################################
This section provides additional information about known issues with
the CMC Firmware version 1.0 User's Guide.
* On Page 273 of the user's guide, fwupdate racadm subcommand example
states the following:
Example Input: racadm fwupdate -g -u -a 192.168.0.120 firmimg.cmc -m
cmc-active
Output: Firmware update complete.
The output needs to be initially:
TFTP firmware update has been initiated. This update process may take
several minutes to complete.
If this command is typed after the firmware has been completed then you
will see the "Firmware update complete." as output. (181529)
* On Page 164 of the user's guide, Table 6-8 Default Role Group Privileges
lists that the Role group 1, 2 and 3 has the default privilege level set
to Administrator, Power User and Guest User. This needs to be none since
all the role groups default to none.(182570)
* On Page 164 of the User's guide, In Table 6-8 the default privilege for
Power User permissions list is incomplete. It should list the following
permissions: (182570)
CMC Login User
Clear Logs Administrator
Chassis Control Administrator (Power Commands)
Server Administrator
Test Alert User
Fabric A Administrator
Fabric B Administrator
Fabric C Administrator
* On Page 138 of the User's guide, Updating the CMC Firmware section once
the step 4 is attempted, the firmware will transfer and once the firmware
update begins, the status will display "Firmware Update in Progress". Once
the CMC update is complete, it resets the CMC. You will need to refresh
the User Interface page to then relogin. (186490)