Owner's Manual

366 Using the LCD Panel Interface
Critical System Board Current Monitor:
Current sensor for System Board,
failure event
Current crossed a failing threshold.
Critical <voltage sensor name>: Voltage
sensor for System Board, state
asserted was asserted
Voltage out of range.
Critical CPU<number> Status: Processor
sensor for CPU<number>, IERR
was asserted
CPU failure.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
thermal tripped was asserted
CPU overheated.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
configuration error was asserted
Incorrect processor type or in
wrong location.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
presence was de-asserted
Required CPU is missing or not
present.
Critical System Board Video Riser: Module
sensor for System Board, device
removed was asserted
Required module was removed.
Critical Mezz B Status: Add-in Card sensor
for Mezz B, install error was
asserted
Incorrect Mezzanine card installed
for IO fabric.
Critical Mezz C Status: Add-in Card
sensor for Mezz C, install error was
asserted
Incorrect Mezzanine card installed
for IO fabric.
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive removed
Storage Drive was removed.
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive fault was asserted
Storage Drive failed.
Table C-8. Server Status Screen for M600/M605 (continued)
Severity Message Cause