Owner's Manual
Using the LCD Panel Interface 365
Critical Local KVM Health: Module sensor
for Local KVM, transition to
critical from less severe was
asserted
USB host enumeration failure or
OSCAR failure.
Non-
Recoverable
Local KVM Health: Module sensor
for Local KVM, transition to non-
recoverable was asserted
Serial RIP failure or USB host chip
failure.
Table C-7. PSU Status Screens
Severity Message Cause
Critical Power Supply PSU <number>:
Power Supply sensor for Power
Supply, failure was asserted
The PSU has failed.
Critical Power Supply PSU <number>:
Power Supply sensor for Power
Supply, input lost was asserted
Loss of AC power or AC cord
unplugged.
Table C-8. Server Status Screen for M600/M605
Severity Message Cause
Warning System Board Ambient Temp:
Temperature sensor for System
Board, warning event
Server Ambient temperature
crossed a warning threshold.
Critical System Board Ambient Temp:
Temperature sensor for System
Board, failure event
Server Ambient temperature
crossed a failing threshold.
Critical System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted
CMOS battery is not present or
has no voltage.
Warning System Board Current Monitor:
Current sensor for System Board,
warning event
Current crossed a warning
threshold.
Table C-6. iKVM Status Screen (continued)
Severity Message Cause