Owner's Manual
350 CMC Property Database Group and Object Definitions
cfgChassisPower
NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property, you must have Chassis Configuration
Administrator privilege.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the
output. To modify a configurable object, use the -o option.
Description
Displays information for and configures power for the chassis.
cfgChassisRedundancPolicy
Sets the redundancy policy of the chassis.
Configuration options: 0 (no redundancy), 1 (AC redundancy), 2 (power
supply redundancy).
Default: 0 (no redundancy)
# cfgChassisRedundantState
Read only. Enables or disables power redundancy for the chassis.
Values: 0 (none), 1 (full)
cfgChassisDynamicPSUEngagementSet
Enables or disables dynamic engagement.
Configuration options: 0 (disabled), 1 (enabled)
Default: 0 (disabled)
# cfgChassisPowerStatus
Read only. Indicates the power status of the chassis.
Configuration options: 1 (other), 2 (unknown), 3 (OK), 4 (non-critical), 5
(critical), 6 (non-recoverable)
# cfgChassisAvailablePower
Read only. Indicates the amount of power (in watts) available for use by the
chassis.