Owner's Manual

Power Management 199
5
Select one of the following
Power Control Operations
by clicking its radio
button:
Power On System
— Turns on the system power.
Power Off System
— Turns off the system power.
Reset CMC
— Resets the CMC without powering off (warm reboot).
(This option is disabled if the CMC is already powered off).
NOTE: This action only resets the CMC. No other components are affected.
Power Cycle System
— Power off, then reboot (cold boot) the system.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example, cause
the system to reset).
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm chassisaction -m chassis <
action
>
where
<
action
> is
powerup, powerdown, powercycle, or reset.
Executing Power Control Operations on an IOM
You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
Using the Web Interface
1
Log in to the CMC Web interface.
2
Select
I/O Modules
. The
I/O Modules Status
page displays.
3
Click the
Power Management
tab. The
Power Control
page displays.
4
Select the operation you want to execute (
reset
or
power cycle
) from the
drop-down menu beside the IOM in the list.
5
Click
Apply
. A dialog box appears requesting confirmation.
6
Click
OK
to perform the power management action (for example, cause
the IOM to power cycle).