Owner's Manual

198 Power Management
Using the Web Interface
1
Log in to the CMC Web interface.
2
Click
Chassis
in the system tree. The
Component Health
page appears.
3
Click the
Power Management
tab. The
Power Budget Status
page appears.
4
Click the
Configuration
sub-tab. The
Budget/Redundancy Configuration
page appears.
5
Select the
Server Power Throttling Enabled
check box.
6
Click
Apply
to save your changes.
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm config -g cfgChassisPower -o
cfgEnablePerformanceDegradation <
option
>
where <
option
> is 0 (disable), or 1 (enable).
Executing Power Control Operations on the Chassis
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
NOTE: Power control operations affect the entire chassis. For power control
operations on an IOM, see "Executing Power Control Operations on an IOM" on
page 199. For power control operations on servers, see "Executing Power Control
Operations on a Server" on page 200.
The CMC enables you to remotely perform several power management
actions, such as an orderly shutdown, on the entire chassis (chassis, servers,
IOMs, iKVM, and PSUs).
Using the Web Interface
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Power Management
tab. The
Power Budget Status
page
displays.
4
Click the
Control
sub-tab. The
Power Management
page displays.