Messages Reference Guide
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0216
Message The disk drive bay
arg1
voltage is outside of range.
Arguments
•
arg1 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect
all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0217
Message The disk drive bay
arg1
voltage is within range.
Arguments
•
arg1 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
917